Browsing Electrical Engineering (EE) by Advisor "Narayanan, G"
Now showing items 1-16 of 16
-
AlGaN/GaN Heterojunction Based Hall Sensors for Magnetic Field Sensing over Wide Temperature Range
Hall sensor has proved to be an attractive solution for sensing requirements in electric machines for direct measurement of fields or indirect estimation of physical quantities such as current, speed and torque. Current ... -
Comparative Evaluation Of Space Vector Based Pulse Width Modulation Techniques In Terms Of Harmonic Distortion And Switching Loss
(2010-09-14)Voltage source inverters (VSI) are popular in variable speed induction motor drive applications. Pulse width modulation (PWM) is employed to achieve variable voltage variable frequency output from a fixed DC bus voltage. ... -
Control, Modulation and Testing of High-Power Pulse Width Modulated Converters
(2018-04-02)Experimental research on high-power converters, particularly in an academic environment, faces severe infrastructural constraints. Usually, power source and loads of required ratings are not available. Further, more ... -
Dead-Time Induced Oscillations in Voltage Source Inverter-Fed Induction Motor Drives
(2017-12-07)The inverter dead-time is integral to the safety of a voltage source inverter (VSI). Dead-time is introduced between the complementary gating signals of the top and bottom switches in each VSI leg to prevent shoot-through ... -
Emulation of wind turbine and sensorless control of doubly-fed induction generator for wind energy application
Wind energy utilization has been growing at a rapid rate, fuelling research and development in wind turbine – generator systems. Doubly fed induction generator (DFIG) driven by a wind turbine is a commonly used wind energy ... -
Experimental Studies on Acoustic Noise Emitted by Induction Motor Drives Operated with Different Pulse-Width Modulation Schemes
(2018-08-13)Voltage source inverter (VSI) fed induction motors are increasingly used in industrial and transportation applications as variable speed drives. However, VSIs generate non-sinusoidal voltages and hence result in harmonic ... -
Low Switching Frequency Pulse Width Modulation for Induction Motor Drives
(2018-06-11)Induction motor (IM) drives are employed in a wide range of industries due to low maintenance, improved efficiency and low emissions. Industrial installations of high-power IM drives rated up to 30 MW have been reported. ... -
Modeling, Analysis And Control Of Single-Phase And Three-Phase PWM Rectifiers
(2009-06-16)Pulse width modulation (PWM) rectifiers are extensively used in battery charger, regulated dc voltage source, UPS systems, ac line conditioner and motor drives. The conventional control schemes for these rectifiers require ... -
Modeling, Characterization, Control and Design of Switched Reluctance Machines
Switched reluctance machines (SRM) are permanent magnet free, and have a simple rotor construction with no current carrying parts. These are particularly suitable for high-temperature and high-speed applications. However, ... -
Modelling, Stabilization Methods and Power Amplification for Power Hardware-in-Loop Simulation with Improved Accuracy
Accurate testing of a device under development, in near to real-life environment, is essential to the rapid growth of emerging technologies such as distributed generation, renewable energy sources, electrical storage, ... -
PWM Techniques for Split-Phase Induction Motor Drive
(2018-02-18)A split-phase induction motor (SPIM) is obtained by splitting each of the three-phase stator windings of an induction motor into two equal halves. This results in two sets of three-phase windings with a spatial angle ... -
Space-Vector-Based Pulse Width Modulation Strategies To Reduce Pulsating Torque In Induction Motor Drives
(2015-05-27)Voltage source inverter (VSI) is used to control the speed of an induction motor by applying AC voltage of variable amplitude and frequency. The semiconductor switches in a VSI are turned on and off in an appropriate ... -
Study On DC-Link Capacitor Current In A Three-Level Neutral-Point Clamped Inverter
(2017-05-24)Three-level diode-clamped inverter is being widely used these days. Extensive research has been carried out on pulse width modulation (PWM) strategies for a three-level inverter. The most widely used PWM strategies are ... -
Study On Overmodulation Methods For PWM Inverter Fed AC Drives
(Indian Institute of Science, 2007-05-10)A voltage source inverter is commonly used to supply a variable frequency variable voltage to a three phase induction motor in a variable speed application. A suitable pulse width modulation (PWM) technique is employed to ... -
Study on Pulsewidth Modulation Techniques for a Neutral-Point-Clamped Voltage Source Inverter
(2018-02-23)Neutral-point-clamped (NPC) three-level inverter is capable of handling higher dc bus voltage and producing output waveform of better quality than a conventional two-level inverter. The main objective of the present work ...