Dynamics of Bubbles and Drops in the Presence of an Electric Field
Abstract
The present thesis deals with two-phase electrohydrodynamic simulations of bubble and droplet dynamics under externally applied electric fields. We used the Coupled Level-Set and Volume-of-fluid method (CLSVOF) and two different electrohydrody-namic formulations to study the process of bubble and drop formation from orifices and needles, the interactions of two conducting drops immersed in a dielectric medium, and the oscillations of sessile drops under two different ways of applying external elec-tric field.
For the process of bubble formation in dielectric liquids due to the injection of air from submerged orifices and needles, we show that a non-uniform electric field pro-duces smaller bubbles while a uniform electric field changes only the bubble shape. We further explain the reason behind the bubble volume reduction under a non-uniform electric field. We show that the distribution of the electric stresses on the bubble inter-face is such that very high electric stresses act on the bubble base due to a non-uniform electric field. This causes a premature neck formation and bubble detachment lead-ing to the formation of smaller bubbles. We also observe that the non-uniform elec-tric stresses pull the bubble interface contact line inside the needle. With oscillatory electric fields, we show that a further reduction in bubble sizes is possible, but only at certain electric field oscillation frequencies. At other frequencies, bubbles bigger than those under a constant electric field of strength equal to the amplitude of the AC electric field, are produced. We further study the bubble oscillation modes under an oscillatory electric field.
We implemented a Volume-of-fluid method based charge advection scheme which is charge conservative and non-diffusive. With the help of this scheme, we were able to simulate the electrohydrodynamic interactions of conducting-dielectric fluid pairs. For two conducting drops inside a dielectric fluid, we observe that they fail to coalesce when the strength of the applied electric field is beyond a critical value. We observe that the non-coalescence between the two drops occur due to the charge transfer upon drop-drop contact. The electric forces which initially bring the two drops closer, switch direction upon charge transfer and pull the drops away from each other. The factors governing the non-coalescence are the electric conductivity of the drop’s liquid which governs the time scale of charge transfer relative to the capillary time scale and the magnitude of the electric forces relative to the capillary and the viscous forces. Similar observations are recorded for the interactions of a charged conducting drop with an interface between a dielectric fluid and a conducting fluid which is the same as the drop’s liquid.
For the case of a pendant conducting drop attached to a capillary and without any influx of liquid from the capillary, we observed that the drop undergoes oscillations at lower values of electric potential when subjected to a step change in the applied electric potential. At higher values of electric potential, we observed the phenomenon of cone-jet formation which results due to the accumulation of the electric charges and thus the electric forces at the drop tip. For the formation of a pendant conducting drops from a charged capillary due to liquid injection, we observed that the drops are elongated in presence of an electric field. This happens because the free charge which appears at the drop tip is attracted towards the grounded electrode. This also leads to the formation of elongated liquid threads which connect the drop to the capillary during drop detachment. We plotted the variation of total electric charge inside the drops with respect to time and found the charge increases steeply as the drop becomes elongated and moves towards the grounded electrode.
For sessile drop oscillations under an alternating electric field, two different modes of operations are studied. In the so called ‘Contact mode’ case, the droplet is placed on a dielectric coated grounded electrode and the charged needle electrode remains in direct contact with the drop as it oscillates. In the ‘Non-contact mode’ case, the drop is placed directly on the grounded electrode and electric potential is applied to a needle electrode which now remains far from the drop. We show that the drop oscillations in the contact mode are caused by concentration of electric forces near the three phase contact line where the electric charge accumulates because of the repulsion from the needle. For the non-contact mode, we observe that the electric charge is attracted by the needle towards the drop apex resulting in a concentration of the electric forces in that region. So the drop oscillates due to the electric forces acting on a region near the drop tip. We also present the variation of the total electric charge inside the drop with respect to time for the two cases studied.
Collections
Related items
Showing items related by title, author, creator and subject.
-
Studies In The Dynamics Of Two And Three Wheeled Vehicles
Karanam, Venkata Mangaraju (2016-09-09)Two and three-wheeled vehicles are being used in increasing numbers in many emerging countries. The dynamics of such vehicles are very different from those of cars and other means of transportation. This thesis deals with ... -
Structure And Dynamics Of Constrained Water : Microscopic Study Of Macromolecular Hydration Using Computer Simulations
Pal, Subrata (2010-06-04)The thesis, which contains nine chapters, reports extensive large scale atomistic molecular dynamics (MD) simulation studies of water structure and dynamics at the surface of an anionic micelle, hydration layer of two ... -
Stochastic Modelling of Vehicle-Structure Interactions : Dynamic State And Parameter Estimation, And Global Response Sensitivity Analysis
Abhinav, S (2017-10-31)The analysis of vehicle-structure interaction systems plays a significant role in the design and maintenance of bridges. In recent years, the assessment of the health of existing bridges and the design of new ones has ...