Show simple item record

dc.contributor.advisorGopinath, K
dc.contributor.authorMuppalaneni, Nitin
dc.date.accessioned2005-02-08T09:35:50Z
dc.date.accessioned2018-07-31T07:08:13Z
dc.date.available2005-02-08T09:35:50Z
dc.date.available2018-07-31T07:08:13Z
dc.date.issued2005-02-08T09:35:50Z
dc.date.submitted1998
dc.identifier.urihttps://etd.iisc.ac.in/handle/2005/3926
dc.identifier.srnonull
dc.description.abstractRedundant Arrays of Inexpensive Disks or RAID is a popular method of improving the reliability and performance of disk storage. Of various levels of RAID, mirrored or RAID1 and rotating parity or RAID5 configurations have become moat popular. Mirrored or RAID1 provides best overall performance and is easier to configure, but has 100 percent storage overhead for the redundancy. Rotating parity or RAID5, on the other hand, is quite inexpensive for the redundancy it provides, shorn impressive performance for reads and full-stripe writes in normal mode, but the small write performance is poor due to the read-modify-write cycle involved. The performance drops drastically when one of the disks fails and the system enters degraded mode. Also RAID5 is relatively difficult to configure. Typical non-scientific system disk access patterns exhibit very high locality of reference. This thesis presents the design and implementation of an Adaptive Hierarchical RAID array to exploit this high locality. Frequently accessed data is migrated towards the top of the hierarchy and not so frequently acee88ed data is moved down the hierarchy, thus adaptively rearranging itself to the access patterns. Previous work on Adaptive Hierarchical RAID such as HP AutoRAID has explored one part of the design space, namely design of configurable storage at the SGSI level with no interaction with higher level layers like volume manager. This thesis explores a different design point: namely, one that is centered at the volume manager layer. This is important also for the reason that with fibre channel disks and SCSI-3, Storage Area Networks (SAN) no longer need a conventional controller but a modified version of a controller that is more close to a volume manager.en
dc.format.extent1725310 bytes
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.publisherIndian Institute of Scienceen
dc.rightsI grant Indian Institute of Science the right to archive and to make available my thesis or dissertation in whole or in part in all forms of media, now hereafter known. I retain all proprietary rights, such as patent rights. I also retain the right to use in future works (such as articles or books) all or part of this thesis or dissertation.en
dc.subject.classificationComputer and Information Scienceen
dc.subject.keywordMemory hierarchy(Computer science)en
dc.subject.keywordComputer storage disksen
dc.subject.keywordRAIDen
dc.subject.keywordRedundant Arrays of Inexpensive Disksen
dc.subject.keywordTemperature Sensitive Storage (TSS)en
dc.titleAdaptive Hierarchial RAIDen
dc.typeElectronic Thesis and Dissertationen
dc.degree.nameMSc Engg.en
dc.degree.levelMastersen
dc.degree.grantorIndian Institute of Scienceen
dc.degree.disciplineFaculty of Engineeringen


Files in this item

This item appears in the following Collection(s)

Show simple item record