dc.description.abstractHeat pipes are extensively used in spacecraft thermal control and electronics cooling for transfer of heat from high heat flux zones to low heat flux zones. The major advantage of heat pipe is it can transfer high heat flux with minimum temperature difference between the source and sink. Capillary forces generated by wick drives the fluid between condenser and evaporator. The working fluid collects heat in the evaporator, vaporizes and moves towards condenser. The vapour condenses back to liquid in the condenser by releasing the heat to surroundings. This condensed liquid flows back to the evaporator by capillary forces generated by wick. Loop heat pipes (LHPs) are provided with wick at evaporator region unlike in conventional heat pipes to reduce the pressure drop and increase heat transport distances. The flat plate LHPs are always preferred due to their simple construction and can be mounted directly onto the electronics package without any saddle. But large heat leak from evaporator to compensation chamber (CC) of flat LHPs is their major drawback, which needs to be studied meticulously. Extensive research has been carried out for understanding the steady state and transient characteristics of an LHP with different heat loads and working fluids. However, the literature lacks in the study of heat leak into the CC and its effect on its operating characteristics, particularly at high heat loads or catastrophic operating conditions. The present study of heat leak into the CC of an LHP evaporator is a step forward for better understanding of the phenomena occurring in the CC and their effect on the heat transfer characteristics with acetone as working fluid. An optically accessible evaporator setup is built to visualize the phenomena inside the CC of capillary evaporator using high speed camera and two different thermal conductive material wicks, i.e., Bronze and UHMW-PE. Visualization inside the CC is carried out for bubble dynamics and correlated against heat loads. Heat transport capability at different operating regimes is evaluated and it is found that the highest evaporative heat transfer coefficient is achieved at the onset of nucleate boiling. Wick temperature overshoot is witnessed during start-up of the flow while using Bronze wick, but no such phenomenon is observed for UHMW-PE wick. This is attributed to higher thermal conductivity of Bronze wick, which would delay to attain required motive temperature head (second serviceability condition) to displace liquid into CC. The start-up duration decreases steeply with increase in heat load for both the wicks. It was found the probability of bubble size mostly depends on the wick pore size and marginally on heater power. As the bubble frequency (which is the measure of energy carried by bubbles) changes significantly with heater power, bubble dynamics have substantial implication on the evaporative heat transfer coefficient. Global heat balance across the capillary evaporator is carried out and presented. Heat leak through the wicks (i.e., heat leak through temperature measurement and heat leak estimated from correlation) are compared and their effects on the heat transfer characteristics are also discussed.en_US
dc.language.isoen_USen_US
dc.rightsI grant Indian Institute of Science the right to archive and to make available my thesis or dissertation in whole or in part in all forms of media, now hereafter known. I retain all proprietary rights, such as patent rights. I also retain the right to use in future works (such as articles or books) all or part of this thesis or dissertationen_US
dc.subjectLoop Heat Pipeen_US
dc.subjectBubble Dynamicsen_US
dc.subject.classificationResearch Subject Categories::TECHNOLOGY::Materials science::Functional materialsen_US
dc.titleHeat Transfer and Visualization Studies in the Evaporator of a Flat Loop Heat pipeen_US
dc.typeThesisen_US
dc.degree.namePhDen_US
dc.degree.levelDoctoralen_US
dc.degree.grantorIndian Institute of Scienceen_US
dc.degree.disciplineEngineeringen_US


Files in this item

This item appears in the following Collection(s)

Show simple item record